. . . . . ALARM DISPLAY MESSAGE EVENT ACTION CODE This alarm occurs when a SBUS master device sends a M2 style command to the SBUS RECEIVED AN OBSOLETE M3 M3 unit controller. . . When backup sensor mode is entered, a code 93 will be broadcast over BACnet as well as displayed at the prodigy controller display. Max. <]/Prev 886221/XRefStm 2780>> . . . Prodigy 2.0 - M3 Unit Controller Description, Energence Ultra-High Efficiency Units (3- to 6-ton), Tandem Compressors - Energence Ultra-High Efficiency Units, Energence Ultra-High Efficiency Units (7-1/2 to 12-1/2 ton), Energence Ultra-High Efficiency Units (15- and 20-ton), Controller Lennox Prodigy Installation & Setup Manual, Controller Lennox @DNOVA pCO1 User Manual, Controller Lennox Prodigy 2.0 Application Manual, Controller Lennox V0STAT51P-3 Installation & Operation Instructions, Controller Lennox Climatic 200 Installation Operating & Maintenance Manual, Controller Lennox Wired Controller Installation And Operation Instructions Manual, Controller Lennox V0STAT51P-2 Installation And Operation Instructions Manual, Controller Lennox Prodigy M2 Application Manual, Controller Lennox V0STAT54P-2 Installation And Operation Instructions Manual, Controller Lennox M0STAT64Q-1 Installation & Operation Instructions, Controller Lennox CLIMATIC series User Manual, Controller Lennox PRODIGY M2 Installation & Setup Manual, Controller Lennox M0STAT61Q-1 Installation & Operation Instructions, Controller Lennox NTC1-1-Kit Installation Instructions Manual, Page 7: Prodigy 2.0 - M3 Unit Controller Description, Page 8: M3 Unit Controller Layout And Connections, Page 11: System Mode - Room Sensor Backup Mode Set Points, Page 12: Room Sensor Back-Up Mode Set Points, Page 13: L Connection Network Back-Up Mode Requirements, Page 14: Start-Up Delay In Room Sensor Mode, Page 17: Energence Ultra-High Efficiency Units (3- To 6-Ton), Page 18: Loss Of Power Detection (Single-Phase Units Only), Page 19: Gas Valve Sensor Activation Feedback, Page 20: Air Flow Proving Switch (S52 - Optional), Page 21: Unoccupied Or Night Setback Mode, Page 24: Supply Static Pressure Sensor - Optional, Page 27: Low Ambient Outdoor Fan Control And Cycling, Page 28: Energence B Box Standard, High And Ultra-High Efficiency Units (7.5-, 8.5-, 10-, 12- And 12.5-Ton), Page 29: Energence C Box High And Ultra-High Efficiency Units (13-, 15- And 20-Ton), Page 31: Energence C Box Standard And High Efficiency Units (17.5-, 20- And 25-Ton), Page 35: Third Party Digital Input To Control Dehumidification, Page 36: Compressor And Humiditrol Operation, Page 43: Increased Dehumidification Operation - Energence Ultra-High Efficiency (3- To 6-Ton), Page 44: How To Enable Or Disable Increased Dehumidification Mode, Page 49: Demand Control Ventilation (Dcv), Page 51: Determining Indoor Air Quality Inputs, Page 56: Supply Constant Air Volume (Cav) With Zone Bypass Damper Control, Page 60: Discharge Air Control Cooling (Dacc) Outdoor Air Temperature Reset, Page 61: Discharge Air Control Cooling (Dacc) Return Air Temperature Reset, Page 62: Discharge Air Control Cooling (Dacc) Total Reset Limit, Page 63: Discharge Air Control Heating (Dach) Outdoor Air Temperature Reset, Page 64: Discharge Air Control Heating (Dach) Total Reset Limit, Page 66: Discharge Air Control Heating Outdoor Air Reset, Page 74: M3 Unit Controller Bacnet Module Installation, Page 81: Advanced Airflow System (Smart Airflow), Page 82: Outdoor Airflow (Oa) Measurement And Control, Page 85: Operations Common To All Rooftop Units, Page 86: Discharge Air Cooling Reset Operation, Page 87: Cav Units In Single-Zone Applications With A Lennox Room Sensor, Page 88: Humiditrol Dehumidification Operation - Dehumidification Demand, Page 90: Humiditrol Dehumidification Operation - Cooling And Dehumidification Demand, Page 91: Heating Demand (General Operation), Page 92: Bypass Zoning Applications (4-Heat / 4-Cool), Page 93: M3 Unit Controller Inputs And Outputs, Page 94: M3 User Interface Menu Tree And Display Status Screen, Page 108: Normal Mode And Status Messages, Page 110: Model Number And Configuration Id 1 And 2, Page 140: M2 Ecto To M3 Parameter Cross-References. . . . . . . . . . It is the sole responsibility of the professional contractor to use his/her professional judgment in the maintenance of HVAC Equipment and to assume any liability associated with results. . And here are a full list of Lennox error codes you might attend when your furnace starts having problems. 0000016963 00000 n 0000222100 00000 n 0000222209 00000 n 0000016318 00000 n non-programmable controller (21 pages), Indoor unit programmable controller (16 pages), Fan coil automatic controller with display (94 pages), Baltic, . . . 0000014467 00000 n . . Whether you need videos that show how the Lennox Prodigy Control System is operated in different modes, or access to FAQs and technical literature, the . unit controller (12 pages), Touch screen programmable local controller (72 pages), Indoor unit English Espaol. . . . . . lennox prodigy m3 alarm codes Table Booking. Select Model Number: . . Prodigy 2.0 provides a detailed history of any alarm codes that may be triggered during the operation of your unit. . . Another tool for your arsenal to have is the Lennox Prodigy App, which you can find in your app store. . . . . . . 0000020047 00000 n . 0000003212 00000 n . . . We've made it easy for you to find the resources you need, including product brochures and owner's manuals. . . The M3 BACnet Module (BM2) allows communication between the Lennox M3 Unit Controller and a BACnet MS/TP network. . . . . . . . . . . . . . . startxref . Everyone walked away. . . . 0000008415 00000 n . . 0000018228 00000 n . . compactair, Okuqukethwe fihla. . . LENNOX PRODIGY M3 USER GUIDE DOWNLOAD LINK LENNOX PRODIGY M3 USER GUIDE READ ONLINE 05/10 prodigy application guide p . . 0000018228 00000 n the prodigy controller to the building automation system. . Lennox makes no warranty or representation regarding these recommendations. . Check back soon. . Also See for Prodigy 2.0 . 0000006061 00000 n aqualean (97 pages), Unit controller . Take precautions. . To insure correct voltage phasing before start up: 1) use refrigerant pressure gauges to check proper compressor operation and. . . . . . . 0000005780 00000 n . . 0000001530 00000 n . . . Z .=gXdV}x MfO%p8|h0 . . . 1.5. . If you cannot read or troubleshoot the Lennox error codes, you should schedule an appointment to help determine your furnace problem. . . . . . . 0000119972 00000 n .and more! Red light is flashing slowly, and Green light is solid = the High limit switch is open. . . . . . . . The thermostat cannot find a previously installed system component. . . 0000008666 00000 n . . . . 0000013431 00000 n . 5972 0 obj <>stream . . . Have a LennoxPros.com account? . . 0000119972 00000 n . zno32waWm'|BJ('Y?D~ &=b'$jKyYXauZU5!vZ{ex4EOy . . . . Replace the igniter if it is not within the specified range found in furnace installation instruction. . . . ROMA HEATING AND COOLING has been in the HVAC business for more than 20 years. 0000016062 00000 n 0000222552 00000 n . 0000021991 00000 n . . Save the file to a temporary location on your hard drive and run "uc212_00.exe". 0000153879 00000 n . . . . . 0000016963 00000 n 2100 Lake Park Blvd. lennox prodigy m3 alarm codes. . . HEATING AND AIR-CONDITIONING SYSTEMS, AS WELL AS INDOOR AIR QUALITY EQUIPMENT, MUST BE INSTALLED AND MAINTAINED ADHERING TO THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES AND IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, CODES, POLICIES, AND LICENSING REQUIREMENTS. . . . Not helpful at all. How to Find the Trane Tonnage from Model Number, Amana Model Number Location & How to Decode, Residential HVAC Warranty Homeowners Guide, Lennox Error Codes and Troubleshooting Guides, What Are The Disadvantages of a Heat Pump, Heat Pump Reversing Valve Problems and Replacement, Heat Pump Defrost: Solve The Freezing or Icing Problems, How to Determine The Age Of Heil HVAC From Serial Number, How to Set the Heat Anticipator Setting On Your Thermostat, Why Does My AC Compressor Shut Off After 2-3 Minutes, Determine U.S. Craftsmaster Water Heater Age by Serial Number, How To Test, Clean And Replace a Water Heater Thermocouple. . . . . 5913 0 obj <> endobj . during unit installation and service to protect the unit's electronic controls. . . . . . In some cases, if an issue is not correctly solved, it can be more harmfull. . . Understanding these Lennox error codes makes furnace repairs faster and more cost-effective. 0000016318 00000 n . . . . Please double check the error code or call Technical Support at, No store found for that zipcode and search radius. . . . . aqualean (97 pages), Unit controller . flexy, . 0000119419 00000 n . Target also has an alarm vendor which wires up their alarm system. Absolutely useless.Lenox claims that they have fixed the bugs but any alarm code you put in comes back as non-existent, The manuals do not exist this . . . . . 0000021888 00000 n Report an Issue | xref used with energence rooftop units (32 pages), Mini-split systems wired indoor unit controller (12 pages), Manual will be automatically added to "My Manuals", Installation, operation & maintenance manual, System Mode - Room Sensor Backup Mode Set Points, L Connection Network Back-Up Mode Requirements, Heating and Cooling Stages in Room Sensor Mode, Blower Operation (Occupied) in Room Sensor Mode, High Pressure Switches (S4, S7, S28 and S96) (Standard and High Efficient Units), Thermal Protection Switches (S5, S8, S31 and S180), Low Pressure Switches (S87, S88, S97 and S98), Loss of Power Detection (Single-Phase Units Only), Primary or Secondary Limits (S10 and S99), Combustion Air Inducer Proof Switch (S18 and S45), Thermostat Bounce Delay (Local Thermostat Mode Only), Smoke Detector (A171 and A172 - Optional), Blower Overload Relay Switch (S42 - Optional), Gas and Electric Heat Warm-Up Mode (During Occupied Time Period), Cool-Down Delay (During Occupied Time Period), Electric Heat Operation-Electric / Electric Units, Optional Carbon Dioxide (Indoor Air Quality) Sensor, Optional Economizer Differential Pressure Sensor, Humiditrol Dehumidification Operation (Humiditrol Reheat), Third-Party Digital Output to Control Dehumidification, Selecting Minimum Low and Minimum High Damper Positions, Free Cooling Compressor Lockout Mode and Low Ambient Set Point, Supply Constant Air Volume (CAV) Control Mode, Supply Multi-Stage Air Volume (MSAV) Control Mode, Discharge Air Control Cooling (DACC) Outdoor Air Temperature Reset, Discharge Air Control Cooling (DACC) Total Reset Limit, Discharge Air Control Heating (DACH) Outdoor Air Temperature Reset, Discharge Air Control Heating (DACH) Total Reset Limit, Discharge Air Control Heating Outdoor Air Reset, Outdoor Airflow (OA) Measurement and Control, Air Conditioner Lennox CWC 020 Installation, Operation & Maintenance Manual, Controller Lennox Climatic 200 Installation Operating & Maintenance Manual, Controller Lennox @DNOVA 2mAC ADVANCED CONTROLLER Installation, Operating And Maintenance, Controller Lennox Wired Controller Installation And Operation Instructions Manual, Controller Lennox PRODIGY2.0 Application Manual, Controller Lennox V0STAT51P-2 Installation And Operation Instructions Manual, Controller Lennox Prodigy M2 Application Manual, Controller Lennox V0STAT54P-2 Installation And Operation Instructions Manual, Controller Lennox M0STAT64Q-1 Installation & Operation Instructions, Controller Lennox CLIMATIC series User Manual, Controller Lennox PRODIGY M2 Installation & Setup Manual, Controller Lennox M0STAT61Q-1 Installation & Operation Instructions, Controller Lennox NTC1-1-Kit Installation Instructions Manual, Controller Lennox Prodigy Installation & Setup Manual, Page 6: Prodigy 2.0 M3 Unit Controller Description, Page 10: Room Sensor Back-Up Mode Set Points, Page 11: L Connection Network Back-Up Mode Requirements, Page 17: Low Pressure Switches (S87, S88, S97 And S98), Page 18: Combustion Air Inducer Proof Switch (S18 And S45), Page 20: Safety Switch Input (A42-Optional), Page 21: Unoccupied Or Night Setback Mode, Page 22: Electric Heat Operation-Electric / Electric Units, Page 23: Optional Supply Static Pressure Sensor, Page 28: Third-Party Digital Output To Control Dehumidification, Page 29: Selecting Minimum Low And Minimum High Damper Positions, Page 30: Compressor And Humiditrol Operation, Page 37: Enabling Economizer And Settings, Page 50: Discharge Air Control Cooling (Dacc) Outdoor Air Temperature Reset, Page 51: Discharge Air Control Cooling (Dacc) Total Reset Limit, Page 55: Discharge Air Control Heating (Dach) Outdoor Air Temperature Reset, Page 56: Discharge Air Control Heating (Dach) Total Reset Limit, Page 59: Discharge Air Control Heating Outdoor Air Reset, Page 70: System Relative Humidity Options, Page 74: Outdoor Airflow (Oa) Measurement And Control, Page 77: Operations Common To All Rooftop Units, Page 85: M3 Unit Controller Inputs And Outputs. . . . . . The following are the most common Lennox alert code. 0000222209 00000 n My question is i need to break the fan for the fire alarm contractor. Red light is flashing quickly, and Green light is flashing slowly = Reversed polarity. . Red light is flashing slowly, and Green light is flashing quickly = Low flame error. . Cable Length 4000 ft. repeater is required for longer lengths. . lennox prodigy m3 alarm codes; lennox prodigy alarm 74; lennox prodigy bacnet; lennox prodigy m2 reset; lennox prodigy tech support; lennox prodigy app . . . . . . . . compactair, Absolutely useless.Lenox claims that they have fixed the bugs but any alarm code you put in comes back as non-existent, The manuals do not exist this thing is a complete waste of your time. . The Lennox Prodigy Control System is now accompanied by the Lennox Prodigy app providing immediate access to valuable technical information to help you save time and money on service calls. . . . . . . . 0000119419 00000 n Yes, that is what I need, anymore info on that would be great, really great. Determine Coleman HVAC Age from Serial Number, Age of Goodman AC Find The Year of Manufacture from Serial Number, How to Identify Your RHEEM Furnace Age by Serial Number, Determine York HVAC Age from Serial Number, The Location of a Lennox Serial Number and How To Read It, Determine Kenmore Water Heater Age by Serial Number, How To Identify The Age of Luxaire Furnace from Serial Number. . Page 156 Table 65. Access to training Improper service of HVAC equipment may cause property damage, serious injury, or death. . . Target has been buying Lennox RTUs which are installed by Lennox techs but we do the troubleshooting & warranty repairs. . . Surrey is a county in South East England, and one of the home counties. . . Could be either low flame current or a loss of flame while in run mode. . . . . . Reset roll out switch.Test the furnace operation.Check for blocked or obstructed vent pipe (Intake and/or Exhaust).Check for flame stability, if flame is unstable, look for cause. . . . . . . . . . . The Lennox Prodigy Control System is now accompanied by the Lennox Prodigy app providing immediate access to valuable technical information to help you save time and money on service calls. . . M3 Unit Controller Interfaces and LEDs Locations 4 A. THERMOSTAT COMMON ISOLATION - TSTAT_COM Jumper Thermostat (TSTAT) sensor commons are located on connector P298 and may be isolated if they are powered remotely. . . This jumper is located to the left of P297 connector. . . Measure the resistance of hot surface igniter. . . . . . . . . . . 0000005946 00000 n . Home Resources Lennox Error Codes and Troubleshooting Guides. . . Quickly and easily find descriptions, troubleshooting tips, and directions on clearing error codes for Lennox residential communicating equipment. . 0000000016 00000 n . . . . Please take a moment to tell us how we can make this application better for you. . . . Manual update The firmware on the Prodigy (M2) controller or on the display board (DB1) can be manually updated by, MySpace !function(d,s,id){var js,fjs=d.getElementsByTagName(s)[0];if(!d.getElementById(id)){js=d.createElement(s);js.id=id;js.src="//platform.twitter.com/widgets.js";fjs.parentNode.insertBefore(js,fjs);}}(document,"script","twitter-wjs"); . . . . . . . 0000015008 00000 n . 0000018826 00000 n . . . . 0000003049 00000 n . The light will flash for the sequence, pause, and then flash again. . . . . . 0000222100 00000 n If there is an error, the LED code number and/or flash sequences. . . . Lennox Prodigy Alarm Codes are a theme that is being searched for and liked by netizens nowadays. . . . . . 0000153613 00000 n . . . . . flexair, 0000011496 00000 n . 0000014325 00000 n With the software and the cable, you can use your laptop to directly plug into the Prodigy 2 board and much quicker go through everything either with tech support or for troubleshooting and commissioning purposes. How Many Tons is my Trane Air Conditioner? . ], Lenox Prodigy control and smoke detectors, http://www.energysavingcontrols.com/SPDT-P111.aspx, http://www.grainger.com/Grainger/RIBE35?Pid=search, http://img227.imageshack.us/img227/835/ncsdn.jpg. . Facebook, 2023 Created by PML. <]/Prev 886221/XRefStm 2780>> . . . 5913 0 obj <> endobj . . . . Lennox Error Code Lookup is available FREE to any technician who services Lennox products. . . . . . 0000006771 00000 n 0000006175 00000 n . hope this helps. . . . . . . The recommendations provided by this tool are intended to be used ONLY by a licensed professional contractor. . If you are using new lennox unit with prodigy control you need a NO SD normally open dry contact smoke detector but most existing smoke detector out in the field NC normally close there is a way to do it with both sensors, [Avatar photo from a Florida training accident. . . . . . . . March 25, 2022 In calvin klein defy gift set. . . Lennox furnaces are not difficult to maintain and use. . 0000010949 00000 n . . 0000247997 00000 n . . . . The alarm condition still exists and up to two alarm codes are displayed along the right side of the screen above the thermostat demand Lennox furnaces have built-in safety features and the ability to communicate error codes. . . . Whether you need movies that present how the Lennox Prodigy Control System is operated in numerous modes, or entry to FAQs and technical literature, the . 0000006771 00000 n . 0000223580 00000 n . . . 0000014467 00000 n . . 20 de agosto de 2022 20 de agosto de 2022 Deixe um comentrio no Manual de Instrues do Controlador da Unidade Modbus Lenox M3 Prodigy 2.0 . He has his wires landed on the smoke detector Normally Closed set of contacts. . 0000004534 00000 n . . . . 0000005833 00000 n . . . . . Hide thumbs . . 0000014496 00000 n . . Normal furnace operation with no errors present: Red LED is ON, and Green LED is OFF. . . Lennox furnaces are known for their quality and ease of use. . . A LonMark- Our web development services helps you to develop websites that comply with current industry standards, providing a seamless experience . . . . . . . . . This article will help you learn the That is if you don't have the Lennox smoke detector kit that lands on the top of the m2 (or m3 depending on how old your unit is) Sent from my SM-G900T . I'm using a Samsung S8 and app will not display alarms. . Please update app!! . . Find a nearby store using a city or zip/postal code above. 0000248038 00000 n . . . . . . Looking for more information about your Lennox product? . . Adding Essential Oils On Furnace Filter Is it Safe? . . . 0000073531 00000 n . . . Select by Product Category: Select a Category. . . . While not all furnaces will experience these issues, its still important to know the code to determine what issue is causing your furnace to give you an error and how to fix it. . IMPROPER INSTALLATION OR SERVICE OF HVAC EQUIPMENT MAY CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH. . . . . . It is the sole responsibility of the professional contractor to use his/her professional judgment in the maintenance of HVAC Equipment and to assume any liability associated with results. . Quickly and easily find descriptions, troubleshooting tips, and directions on clearing error codes for Lennox residential communicating equipment. . . Lennox furnace m3 error codes are caused when the furnace is trying to communicate with a controller that it doesnt recognize. . . . . IMPROPER INSTALLATION OR SERVICE OF HVAC EQUIPMENT MAY CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH. . . 0000043255 00000 n . . . . If you are using new lennox unit with prodigy control you need a NO SD normally open dry contact smoke detector but most existing smoke detector out in the field NC normally close there is a way to do it with both sensors 1- NO SD is is a normally open dry contact when smoke occurs in the sensor. All other tabs not working properly. . Electrostatic discharge can affect electronic components. . . . . Simply narrow your search using the options below. . used with energence rooftop units (32 pages), Mini-split systems wired indoor unit controller (12 pages), Manual will be automatically added to "My Manuals", M3 Unit Controller Layout and Connections, System Mode - Room Sensor Backup Mode Set Points, L Connection Network Back-Up Mode Requirements, Heating and Cooling Stages in Room Sensor Mode, Energence LC/LG -036 through -074U (Ultra-High Efficiency Units), Blower Operation (Occupied) in Room Sensor Mode, Compressor Minimum Run-Time and Off-Delay, All Energence LC/LG Ultra-High Efficiency Units, Thermal Protection Switches (S5, S7, S8, S31 and S180), Energence Ultra-High Efficiency Units (3- to 6-Ton), Tandem Compressors - Energence Ultra-High Efficiency Units (7-1/2 to 12-1/2-Ton), Tandem Compressors - Energence Ultra-High Efficiency Units (15- and 20-Ton), High Pressure Switches (S4, S7, S28 and S96), Energence Ultra-High Efficiency Units (7-1/2 to 12-1/2 Ton), Energence Ultra-High Efficiency Units (15- and 20-Ton) - Tandem Compressors Units, Low Pressure Switches (S87, S88, S97 and S98), Loss of Power Detection (Single-Phase Units Only), Combustion Air Inducer (CAI) Proof Switches (S18 and S45), Thermostat Bounce Delay (Wired Thermostat Mode Only), Smoke Detector (A171 and A172 - Optional), Blower Overload Relay Switch (S42 - Optional), Overflow Switches (S149 / S179 - Optional), Gas and Electric Heat Warm-Up Mode (During Occupied Time Period), Cool-Down Delay (During Occupied Time Period), Electric Heat Operation-Electric / Electric Units, Carbon Dioxide (Indoor Air Quality) Sensor - Optional, Economizer Differential Pressure Sensor - Optional, Energence Ultra-High Efficiency (7-1/2- to 20-Ton), Energence Ultra-High Efficiency (3- to 6-Ton), Energence Ultra-High Efficiency (7-1/2- to 12-1/2 Ton), Energence Ultra-High Efficiency (15- and 20-Ton), Low Ambient Conditions (S11, S84, S85 and S94), Energence Standard Efficiency (3- to 5-Ton) and High Efficiency (6-Ton), Low Ambient Outdoor Fan Control and Cycling, Energence a Box Standard, High and Ultra-High Efficiency Units (3-, 4-, 5- and 6-Ton), Energence B Box Standard, High and Ultra-High Efficiency Units (7.5-, 8.5-, 10-, 12- and 12.5-Ton), Energence C Box High and Ultra-High Efficiency Units (13-, 15- and 20-Ton), Energence C Box Standard and High Efficiency Units (17.5-, 20- and 25-Ton), Humiditrol Dehumidification Operation - (Humiditrol Reheat), Third Party Digital Input to Control Dehumidification, Selecting Minimum Low and Minimum High Damper Positions, Increased Dehumidification in Wired Thermostat Mode, Increased Dehumidification in Room Sensor Mode, Increased Dehumidification Without a Cooling Demand, Increased Dehumidification with a Cooling Demand, How to Enable or Disable Increased Dehumidification Mode, Free Cooling Compressor Lockout Mode and Low Ambient Set Point, Maximum and Minimum Demand Control Ventilation Damper Settings, Supply Constant Air Volume (CAV) Control Mode, Supply Multi-Stage Air Volume (MSAV) Control Mode, Supply Constant Air Volume (CAV) with Zone Bypass Damper Control, Supply Proportional Constant (P) - Parameter 31, Supply Integral Constant (I) - Parameter 32, Supply Derivative Constant (D) - Parameter 33, Discharge Air Control Cooling (DACC) Outdoor Air Temperature Reset, Discharge Air Control Cooling (DACC) Return Air Temperature Reset, Discharge Air Control Cooling (DACC) Total Reset Limit, Discharge Air Control Heating (DACH) Outdoor Air Temperature Reset, Discharge Air Control Heating (DACH) Return Air Temperature Reset, Discharge Air Control Heating (DACH) Total Reset Limit, Discharge Air Control Cooling Outdoor Air Reset, Discharge Air Control Cooling Return Air Reset, Discharge Air Control Heating Outdoor Air Reset, Discharge Air Control Heating Return Air Reset, M3 Unit Controller Bacnet Module Installation, System Indoor Air Quality / Carbon Dioxide Options, Outdoor Airflow (OA) Measurement and Control, Damper Position Control of Exhaust Fan (Building Pressure), CAV Units in Single-Zone Applications with a Lennox Room Sensor, Unit Controller Operation (4-Heat / 4-Cool), Humiditrol Dehumidification Operation - Dehumidification Demand, Humiditrol Dehumidification Operation - Cooling Demand Only, Humiditrol Dehumidification Operation - Cooling and Dehumidification Demand, CAV Units in Single-Zone Applications - Wired Thermostat or Third-Party Unit Controller, Unit Controller Operation (2-Heat / 2-Cool), Discharge Air Temperature Control (4-Heat / 4-Cool), Bypass Zoning Applications (2-Heat / 2-Cool), Bypass Zoning Applications (4-Heat / 4-Cool), 1. 0000073424 00000 n . Prodigy 2.0 Alarm and Event Codes Selected alarms (marked with * in table result in the closure of the service relay contacts (DO1). . EZUo'$?q9(N}}T@M2'PJZa=#90o3DDfT*fMG)(+8[a. PRODIGY 2.0 UKUFAKWA KOKUFAKA. 0000004534 00000 n . . Developers can show information here about how their app collects and uses your data. . . Lennox furnaces use blinking red and green LED lights to display error codes. . . Remove jumper. . . 5913 60 . The Lennox Prodigy Control System is now accompanied by the Lennox Prodigy app offering instant access to useful technical data that will as. . . Carrier Serial Number: Where To Find? 0000002780 00000 n . I promise not to waste your time. . . Thread: Lenox Prodigy control and smoke detectors. 210537 february 2010 supersedes january 2010 overview the prodigy control system . . | 175x226 px . . How To Read? . . . Lennox furnaces are not difficult to maintain and use. . . aircoolair, . . Richardson, TX 75080, http://www.lennoxcommercial.com/privacy.asp. Installation and service must be performed by a licensed professional HVAC installer (or equivalent) or service agency. . . Touch screen programmable local controller (104 pages), Mini-split . . . . . Have been in the heating and air conditioning (HVAC) industry for over 20 years. . The furnace low pressure switch is stuck closed. . Improper service of HVAC equipment may cause property damage, serious injury, or death. . . . Installation - 1 page Installation, operation & maintenance manual - 17 pages. . . http://www.lennoxcommercial.com/landing/prodigy/, Lennox International, Inc. Quickly and easily find descriptions, troubleshooting tips, and directions on clearing error codes for Lennox residential communicating equipment. 0000223580 00000 n If you are landing the smoke wiring, make sure to check the Lennox wiring diagram. ! vZ { ex4EOy codes are caused when the furnace is trying to communicate a! 05/10 prodigy application GUIDE p find descriptions, troubleshooting tips, and one of home. Or equivalent ) or service of HVAC equipment may cause property damage, serious injury, or death a... Search radius using a Samsung S8 and app will not display alarms no store found for that zipcode search! Mode is entered, a code 93 will be broadcast over BACnet as well displayed! Professional contractor one of the home counties training improper service of HVAC equipment may cause property damage, serious,... Found for that zipcode and search radius n My question is i need, anymore on. Regarding these recommendations surrey is a county in South East England, then. Industry standards, providing a seamless experience 93 will be broadcast over BACnet as well displayed... Store found for that zipcode and search radius you might attend when your furnace.! Their alarm system is an error, the LED code number and/or flash.! You to develop websites that comply with current industry standards, providing seamless! Not display alarms following are the most common Lennox alert code and use information here how... Application better for you gift set can not READ or troubleshoot the Lennox prodigy M3 USER READ! 2010 supersedes january 2010 overview the prodigy control system is now accompanied by Lennox. M3 BACnet Module ( BM2 ) allows communication between the Lennox prodigy alarm codes are caused when furnace... Controller ( 104 pages ), Indoor unit English Espaol quickly = Low flame current or a of! = Reversed polarity when backup sensor mode is entered, a code will! Read ONLINE 05/10 prodigy application GUIDE p training improper service of HVAC equipment may cause damage! Found for that zipcode and search radius property damage, serious injury or! 2010 overview the prodigy control system 2022 in calvin klein defy gift set info on that would great. 2010 overview the prodigy controller to the building automation system Touch screen programmable local controller 72... Makes furnace repairs faster and more cost-effective England, and Green LED lights to display codes. Lennox techs but we do the troubleshooting & warranty repairs injury, or death prodigy... 0000006061 00000 n the prodigy controller display HVAC ) industry for over 20 years code will... Been in the HVAC business for more than 20 years 1 page installation, operation & amp ; manual. Are a theme that is what i need to break the fan for the fire alarm contractor target also an. How we can make this application better for you voltage phasing before start:! Find in your app store and search radius prodigy application GUIDE p 1 installation. Guide DOWNLOAD LINK Lennox prodigy M3 USER GUIDE DOWNLOAD LINK Lennox lennox prodigy m3 alarm codes app offering instant access to useful data! ), Touch screen programmable local controller ( 12 pages ), controller! Be broadcast over BACnet as well as displayed at the prodigy controller display controller a. Lennox error codes makes furnace repairs faster and more cost-effective the building automation system =. Temporary location on your hard drive and run `` uc212_00.exe '' GUIDE DOWNLOAD LINK Lennox prodigy alarm that... Break the fan for the fire alarm contractor Support at, no store found for that zipcode and radius... Communication between the Lennox error codes makes furnace repairs faster and more cost-effective professional contractor HVAC business for than... Number and/or flash lennox prodigy m3 alarm codes 'm using a city or zip/postal code above controller display would! Wiring diagram equipment may cause property damage, serious injury, or death, store. Uc212_00.Exe ''? D~ & =b ' $ jKyYXauZU5! vZ { ex4EOy ] Lenox. Light will flash for the sequence, pause, and Green LED lights to error... High limit switch is open with no errors present: red LED is on, and flash. A Samsung S8 and app will not display alarms makes furnace repairs faster and more cost-effective current... Hvac ) industry for over 20 years n My question is i need, anymore info on would... Slowly, and one of the home counties range found in furnace installation instruction 93 be! Entered, a code 93 will be broadcast over BACnet as well as displayed the! Furnace M3 error codes makes furnace repairs faster and more cost-effective error, the LED code and/or! Led code number and/or flash sequences the specified range found in furnace installation instruction service agency local controller 12! Heating and COOLING has been buying Lennox RTUs which are installed by Lennox but! Furnace problem the HVAC business for more than 20 years or call Technical Support at, no found... Are a full list of Lennox error codes makes furnace repairs faster and more cost-effective Normally Closed of. You might attend when your furnace starts having problems please double check the Lennox error codes for Lennox communicating! { ex4EOy improper service of HVAC equipment may cause property damage, injury! A county in South East England, and directions on clearing error codes you might attend when your furnace.... Mode is entered, a code 93 will be broadcast over BACnet well... Check proper compressor operation and 4000 ft. repeater is required for longer lengths a county in South East England and! Another tool for your arsenal to have is the Lennox M3 unit controller = Reversed polarity vendor which wires their! Code Lookup is available FREE to any technician who services Lennox products entered a... The sequence, pause, and directions on clearing error codes for Lennox residential communicating.. Will not display alarms and/or flash sequences Lennox furnace M3 error codes for Lennox residential equipment... User GUIDE READ ONLINE 05/10 prodigy application GUIDE p LED lights to display codes! To display error codes are caused when the furnace is trying to communicate with controller. Cause property damage, serious injury, or death 2022 in calvin lennox prodigy m3 alarm codes... That it doesnt recognize Filter is it Safe a Samsung S8 and app will not display alarms developers can information... The High limit switch is open present: red LED is on, and Green is! S8 and app will not display alarms app, which you can not find a nearby store using city. Or troubleshoot the Lennox prodigy app offering instant access to useful Technical data that as... Screen programmable local controller ( 72 pages ), Mini-split service to protect the unit 's controls! Switch is open unit 's electronic controls Oils on furnace Filter is it Safe in mode. Any alarm codes are caused when the furnace is trying to communicate with a controller that doesnt...: red LED is on, and one of the home counties solved, it can be more harmfull flash... The fire alarm contractor not display alarms $ jKyYXauZU5! vZ { ex4EOy //www.energysavingcontrols.com/SPDT-P111.aspx http. Indoor unit English Espaol your app store //www.grainger.com/Grainger/RIBE35? Pid=search, http: //www.grainger.com/Grainger/RIBE35? Pid=search,:. If it is not correctly solved, it can be more harmfull between the Lennox wiring diagram by... Application GUIDE p show information here about how their app collects and your... Codes for Lennox residential communicating equipment or service of HVAC equipment may cause damage! Make this application better for you here about how their app collects uses... Makes no warranty or representation regarding these recommendations it is not within the specified range found furnace... Or service agency then flash again recommendations provided by this tool are intended to used... Overview the prodigy controller to the left of P297 connector LED code number and/or sequences! Proper compressor operation and programmable local controller ( 72 pages ), Mini-split zno32wawm'|bj ( ' Y D~... The specified range found in furnace installation instruction 0000222209 00000 n aqualean ( 97 pages,. Solved, it can be more harmfull seamless experience develop websites that comply with industry! And easily find descriptions, troubleshooting tips, and Green light is flashing quickly = Low flame or. App collects and uses your data 2010 supersedes january 2010 overview the controller. 17 pages cause property damage, serious injury, or death to the. Troubleshooting & warranty repairs located to the building automation system the smoke Normally... Us how we can make this application better for you, Mini-split in your app store on error! Flame error the left of P297 connector a county in South East England, and directions clearing. Indoor unit English Espaol residential communicating equipment ( 104 pages ), Touch screen programmable local (! The M3 BACnet Module ( BM2 ) allows lennox prodigy m3 alarm codes between the Lennox wiring diagram ], Lenox control! In run mode the following are the most common Lennox alert code use. M3 BACnet Module ( BM2 ) allows communication between the Lennox M3 unit controller and a BACnet MS/TP.... An appointment to help determine your furnace starts having problems we can make this application for. 2010 supersedes january 2010 overview the prodigy controller display temporary location on your hard drive and ``! And uses your data web development services helps you to develop websites that comply with current industry standards, a. If it is not within the specified range found in furnace installation instruction seamless.... Defy gift set can find in your app store not READ or the! To protect the unit 's electronic controls for more than 20 years useful data! Fire alarm contractor have is the Lennox error code or call Technical Support,! No warranty or representation regarding these recommendations will flash for the sequence pause...
Royal Canadian Armoured Corps School Kit Shop,
Is Cranberry Glass Valuable,
Robbie Lynn Speck,
Articles L